Aggregate envelope and pipe displacement
Use this calculator for a conventional aggregate-filled drain envelope with one uniform rectangular section. Enter the length along the run, the aggregate width and the aggregate depth only. Soil cover or other layers above the aggregate are outside this section. This is a material takeoff, not a drainage design or an assessment of excavation safety.
Volume equations
Gross envelope volume = L × W × D. When one pipe is included for the full run, its outside cylindrical envelope displaces π × OD² × L / 4. Net aggregate = gross envelope − pipe displacement. Use actual outside diameter from product data, not the nominal pipe size or inside bore. A cylinder approximates corrugated pipe and excludes fittings. The outside diameter must fit within both aggregate width and depth; this simple check does not establish adequate bedding or cover.
Allowance-adjusted aggregate = net aggregate × (1 + allowance% / 100). The allowance is added once and does not change the pipe run or fabric coverage. It is an estimating extra, not an automatically selected compaction or loose-delivery factor. No mass, bag, truck or supplier order increment is inferred. With pipe displacement disabled, gross envelope equals net aggregate and pipe length is not estimated.
Continuous fabric wrap
The assumed rectangular envelope has one continuous sheet around its bottom, two sides and top. Required strip width = 2W + 2D + entered top closure overlap. Fabric area = strip width × L. The top closure overlap is included once. End closures, joins between successive lengths, sheet splices, offcuts and roll purchase rounding need a separate layout. Check available roll width and the product-specific fabric and overlap requirements. This takeoff does not choose a fabric specification. Disable fabric when it is not part of the approved system.
US worked example
For a 100 ft run with a 12 in wide × 18 in deep aggregate envelope, gross volume is 150 ft³. One pipe with an actual 4 in outside diameter displaces 25π/9 = 8.726646260 ft³. Net aggregate is 141.273353740 ft³, or 5.232346435 yd³. Adding an example 10% allowance gives 155.400689114 ft³, or 5.755581078 yd³. The displayed order estimate is 5.756 yd³; no supplier increment has been applied.
The same envelope has a 5 ft perimeter. With a 12 in top overlap, the strip must cover 6 ft in width and 100 ft in length: 600 ft², excluding its two end closures and any seams. Pipe run is 100 ft without fittings, outlets or extra connections. These editable dimensions are arithmetic examples, not installation specifications.
Metric worked example
A 20 m run with 0.4 m width and 0.6 m aggregate depth has 4.8 m³ gross volume. Actual pipe OD 0.1 m displaces 0.05π = 0.157079633 m³. Net aggregate is 4.642920367 m³; an example 10% allowance gives 5.107212404 m³. An entered 0.3 m top overlap requires a 2.3 m fabric strip and 46 m² before end closures and joins.
Inputs, accuracy and limits
Six length units are supported independently. Unit selectors retain the number entered; choose the unit of that measurement instead of expecting an automatic conversion. Positive dimensions are limited to 0.000001–1,000,000 ft equivalent; overlap may be zero. Gross volume is limited to 1,000,000 m³ and fabric area to 1,000,000,000 m². Allowance is 0–100% with up to four decimal places. These are software bounds, not acceptable design ranges. Hidden pipe/fabric inputs are ignored when their options are off.
Unit conversion, input comparisons and rectangular geometry use decimal fractions. Pipe volume uses JavaScript’s floating-point π, so this is a numerical geometric estimate. Outputs display three decimal places; allowances apply to the unrounded net volume. No drainage flow, rainfall, infiltration, storage void ratio, pipe slope, outlet, filter compatibility, foundations, groundwater, compaction, trench swell or safe excavation support is designed here. The aggregate-filled section may differ from the full excavated section. Follow the approved project and product details.
Primary references
NDS definitive drainage guide describes conventional French drains using perforated pipe, gravel and geotextile. This calculator’s rectangular takeoff equations and fabric layout are explicit assumptions, not an NDS installation specification, and do not apply directly to gravel-free prefabricated bundles. See NIST SP 811 conversion factors for measurement conversions. References checked 4 November 2026. No manufacturer endorsement or independent engineering review is claimed.
Related estimates
Use Trench Excavation for a separate excavated section and swell estimate, or Gravel for a general aggregate takeoff. Neither calculation selects a drainage design.