Concrete volume for solid steps and a landing slab
This calculator estimates a straight series of solid rectangular steps filled down to a common level base. It adds an optional separate landing slab beyond the modeled tread run, repeats that complete set if requested, and applies one concrete allowance to the combined geometric volume. It does not design a staircase or size an inclined structural waist slab.
Understand the tread-count convention
Enter the number of actual formed tread regions, including the top tread and excluding the separate landing. Each tread has the same horizontal depth and stair width. Their heights above the common base are one rise, two rises, three rises and so on to n rises. Modeled tread run is n × tread depth; the top tread height is n × rise. The landing begins beyond that run.
Stair drawings can use different counting conventions, especially when the upper landing serves as the final walking surface. This tool does not automatically subtract one from a riser count. Match the rectangular regions in the model to the concrete regions on your drawing. Do not enter a riser count as a tread count without checking that they describe the same solid geometry.
Solid-step formula
The individual tread regions are non-overlapping vertical rectangular prisms. Their volumes are W × T × R, W × T × 2R, up to W × T × nR. Summing the prism heights gives 1 + 2 + … + n = n(n + 1)/2, so step volume = W × T × R × n(n + 1)/2. W is stair width, T is tread depth and R is rise per tread, all converted into compatible units.
This counts the entire stepped solid down to the common base. It is not the volume of triangular tread wedges over an inclined slab. Hollow cores, compacted fill, sloping grade and other displacements are not deducted. Footings, a base slab below the common base, nosings, surface pitch and reinforcement are not added. Use a separate measured-volume takeoff for construction that differs from this geometry.
Keep the landing slab separate
Landing volume = landing length beyond tread run × landing width × concrete slab thickness. Its width can differ from stair width. Slab thickness is the thickness of concrete, not the landing's elevation above grade. A slab is different from a solid platform filled to the stair height.
The entered landing does not overlap or replace the top tread. Any concrete supports or solid concrete below its slab are outside this component. Add those through a separate reviewed takeoff if needed. Do not add a landing already included in another slab or stair quantity. Disabling the landing removes its volume and ignores its inactive dimensions.
Worked US example
Consider six formed treads, 4 ft wide, each 11 in deep with a 7 in rise. The six prism-height multipliers sum to 21. Solid-step volume is 4 × (11/12) × (7/12) × 21 = 44.916666… ft³. Modeled tread run is 5.5 ft, and top tread height is 3.5 ft above the base.
A separate landing slab 3 ft long, 4 ft wide and 6 in thick adds 6 ft³. Each complete set therefore contains 50.916666… ft³. A 10% example allowance adds 5.091666… ft³, bringing the planning volume to 56.008333… ft³, or 2.074382716… yd³ and 1.5859793828736 m³. Displayed results round to 2.074 yd³, 56.008 ft³ and 1.586 m³. These dimensions and the allowance are arithmetic examples, not recommendations.
Metric example and repeated sets
Four treads 1.2 m wide, 0.3 m deep and rising 0.15 m each contribute 0.054, 0.108, 0.162 and 0.216 m³: a total of 0.54 m³. A separate 1.5 × 1.2 × 0.15 m landing slab adds 0.27 m³. Combined geometry is 0.81 m³; adding 10% gives 0.891 m³.
Identical sets repeat both the steps and the enabled landing. Combined geometric volume = (steps each + landing each) × number of sets. The material allowance is applied once after repetition. A different flight or landing should be measured separately rather than treated as an identical set. Repeating sets does not add their rise or run into a new stair-layout design.
Units, rounding and validation
Each dimension independently accepts ft, in, yd, m, cm or mm. Unit selectors retain numeric entries; they do not convert the displayed number. Exact decimal fractions and the international foot conversion of 0.3048 m are used before output rounding. Cubic yards equal cubic feet divided by 27. No supplier minimum, truckload, bag count or order increment is applied.
Tread count must be a whole number from 1 to 1,000; repeated sets from 1 to 10,000. Converted positive dimensions must lie between 0.000001 and 1,000,000 ft. Dimensions accept up to 18 decimal places. Extra concrete accepts 0–100% with four decimal places. Allowance-adjusted combined volume is limited to one million m³. These are software bounds, not permissible stair dimensions or structural limits.
Frequently asked questions
Does this calculate suspended concrete stairs?
No. It calculates solid filled steps. An inclined waist slab, tread wedges and landing junctions need their own measured geometry and structural design.
Does the landing count as one of the treads?
No. The model counts the entered rectangular treads first and adds a non-overlapping slab beyond their run. Check your drawing's count convention before entering values.
Can I deduct gravel or other fill automatically?
No. The model assumes the step regions are entirely concrete. A supported shell over fill has different geometry and needs a separate takeoff.
Related tools and scope
Use Concrete for separate supported volume shapes, Concrete Slab for a distinct slab takeoff and Concrete Cost for quoted pricing. Quantity arithmetic does not verify accessibility, stair-code compliance, strength, foundations, reinforcement, supports or construction details. See methods and corrections for Civilable's approach to assumptions and software checks.