The Section Properties Calculator finds the area, centroid, centroidal second moments of area, elastic section moduli and radii of gyration of six ideal cross-sections. Choose a solid rectangle, solid circle, rectangular hollow section, circular hollow section, symmetric I-section or top-flange T-section. The results describe geometry about clearly defined axes. They do not establish a member's material strength, load capacity, stability, deflection, connection adequacy or code compliance.
Key Takeaways
- The origin is the bottom-left corner of the outer bounding box. Reported x and y axes pass through the centroid; x is horizontal and y is vertical.
- Area has length-squared units, second moments have length-to-the-fourth units, and section modulus has length-cubed units. Keep these distinct.
- I_x depends on material distribution vertically about the horizontal axis; I_y depends on distribution horizontally about the vertical axis.
- A T-section generally has different top and bottom elastic section moduli because its centroid is not halfway up its height.
- Hollow sections subtract a concentric void. I- and T-sections use non-overlapping rectangles and the parallel-axis theorem.
- The polar area moment J_p=I_x+I_y is not a general torsion constant. It must not be treated as torsional stiffness for an arbitrary shape.
Which section shapes are supported?
All sections are ideal, unrotated planar areas. The rectangle and rectangular hollow section have sharp corners. The circular hollow section has a concentric circular hole. The I-section has equal top and bottom flanges and a centered web. The T-section has one flange at the top and a centered web beneath it.
The tool does not include channels, angles, arbitrary polygons, eccentric holes, unequal I flanges, tapered plates, arbitrary rotations, fillet radii or section-specific fabrication details. Do not approximate an unsupported shape by changing a dimension unless that altered idealization is deliberately established and independently reviewed for the intended use.
The Steel Weight Calculator addresses a different question involving volume and density. This page does not calculate mass. The Beam Reaction Calculator finds ideal external reactions under its stated loads and supports; its reaction results cannot be combined automatically with this page to approve a beam.
Axes, origin and centroid
The coordinate origin lies at the bottom-left of the section's outer bounding box, with x increasing rightward and y upward. For a circle, that corner is a reference point outside the material, not a point on the circumference. The centroid coordinates x̄ and ȳ are measured from this origin.
Reported I_x is about the horizontal line through the centroid, and I_y is about the vertical line through the centroid. These are not moments about the bottom edge or the left edge. The diagram shows the centroid C and these axes to make the distinction visible.
All six supported unrotated shapes have vertical symmetry, so x̄=B/2, using the outer width or diameter as appropriate, and I_xy is zero about the shown centroidal axes. The T-section still has that vertical symmetry, but its horizontal centroidal axis usually lies above half-height because the top flange adds area near the top.
Area centroid is not automatically a material-weighted centroid
The calculation treats the section as one homogeneous geometric area. A built-up section containing materials with different elastic moduli or densities may require a transformed section, stiffness-weighted analysis or mass calculation for the relevant question. Those effects are not included merely by placing two shapes together.
What the reported properties mean
| Property | Definition or role | Units |
|---|
| Area A | Material cross-sectional area after subtracting a supported void | in², mm² |
| Centroid x̄, ȳ | Area-weighted geometric location from the stated origin | in, mm |
| Second moments I_x, I_y | Integrals of squared perpendicular distance over area about the named axes | in⁴, mm⁴ |
| Elastic section modulus S | I divided by the distance to a specified extreme fiber | in³, mm³ |
| Radius of gyration r | √(I/A) for the named axis | in, mm |
| Polar area moment J_p | I_x+I_y about the centroidal perpendicular axis | in⁴, mm⁴ |
A second moment of area is not the mass moment of inertia used in rotational dynamics. Likewise, a section modulus expressed in cubic units is a geometric property, not the volume of material in a member. A real member's length is not an input to this calculation.
Rectangle and circle formulas
Solid rectangle
For width B and overall height H:
- A = BH.
- x̄ = B/2; ȳ = H/2.
- I_x = BH³/12.
- I_y = HB³/12.
Interchanging B and H interchanges I_x and I_y. It does not preserve a physical member's orientation relative to a fixed loading direction. Record the intended orientation beside the dimensions.
Solid circle
For diameter D:
- A = πD²/4.
- x̄ = ȳ = D/2 from the bounding-box origin.
- I_x = I_y = πD⁴/64.
The diameter is the full outside diameter, not the radius. Entering a radius as the diameter changes area by a factor of four and second moment by a factor of sixteen relative to the intended section.
Hollow-section formulas and wall thickness
Concentric rectangular hollow section
With uniform wall thickness t, the inside dimensions are b=B−2t and h=H−2t. Both must remain positive. The formulas are:
- A = BH−bh.
- I_x = (BH³−bh³)/12.
- I_y = (HB³−hb³)/12.
- The centroid remains at B/2, H/2.
This is a sharp-corner idealization. Real rectangular hollow sections can have rounded corners, dimensional tolerances and other details that change their published properties. Use verified manufacturer or recognized section tables for the actual product where required.
Concentric circular hollow section
The inside diameter is d=D−2t, which must be positive. Then A=π(D²−d²)/4 and I_x=I_y=π(D⁴−d⁴)/64. The centroid is at the center of the outer circle.
The tool subtracts the void before rounding. This matters for very thin numerical examples, where an outer and inner dimension can look identical after rounding. It does not mean that an extremely small entered wall thickness is measurable, manufacturable or structurally suitable.
I- and T-sections: composite-area method
The calculator separates an I-section into bottom flange, web and top flange without overlapping their areas. The web height is H−2t_f. For a T-section, the web height is H−t_f, with its bottom at y=0 and the top flange above it. Each web is centered beneath the flange width.
The area-weighted centroid is ȳ=Σ(A_i y_i)/ΣA_i. Each rectangle's own horizontal centroidal second moment is then shifted to the common horizontal centroidal axis:
I_x = Σ[I_xi + A_i(y_i−ȳ)²]
All component rectangles are centered on the same vertical axis in these supported shapes, so their I_y contributions can be added about that shared centroidal vertical axis. The expandable breakdown lists component areas and centroid heights to help trace the calculation.
Engineering Statics: composite shapes explains combining component properties about a common axis, and its parallel-axis theorem section explains the A d² shift. Adding only the separate rectangles' own centroidal I_x values would omit the effect of their vertical separation.
Worked US example: 8-by-12-inch rectangle
Fictional geometry example: an ideal solid rectangle has B=8 in and H=12 in. These are illustrative inputs, not a recommended member size.
- Area A = 8×12 = 96 in².
- Centroid x̄=4 in and ȳ=6 in.
- I_x = 8×12³/12 = 1,152 in⁴.
- I_y = 12×8³/12 = 512 in⁴.
- S_x,top = S_x,bottom = 1,152/6 = 192 in³.
- S_y,left/right = 512/4 = 128 in³.
- r_x = √(1,152/96) = 3.464102 in, rounded.
- r_y = √(512/96) = 2.309401 in, rounded.
- J_p = 1,152+512 = 1,664 in⁴, a polar area moment.
The last number must not be relabeled as this rectangle's torsion constant. The calculation has supplied geometry about the stated axes, without any material, load or boundary-condition assessment.
Worked metric example: 200-by-300-millimeter rectangle
For a separate fictional rectangle with B=200 mm and H=300 mm, A=60,000 mm², x̄=100 mm and ȳ=150 mm. I_x=200×300³/12=450,000,000 mm⁴; I_y=300×200³/12=200,000,000 mm⁴.
The top and bottom elastic section moduli about x are each 450,000,000/150=3,000,000 mm³. The left/right value about y is 200,000,000/100=2,000,000 mm³. The radii are approximately 86.602540 mm and 57.735027 mm. This example is not exactly the same physical size as the 8-by-12-inch example.
Unit powers matter: 1 in² equals 25.4² mm², 1 in³ equals 25.4³ mm³ and 1 in⁴ equals 25.4⁴ mm⁴. Multiplying a fourth-power property by 25.4 alone is an incorrect length-only conversion.
Worked T-section: different top and bottom moduli
Take an ideal top-flange T with B=8 in, H=12 in, t_f=1 in and t_w=0.5 in. The web height is 11 in, so its area is 5.5 in² and its centroid height is 5.5 in. The top flange area is 8 in² at y=11.5 in.
Total area is 13.5 in². The centroid height is (5.5×5.5+8×11.5)/13.5=9.055556 in, rounded, with x̄=4 in. The composite calculation gives I_x=173.458333 in⁴ and I_y=42.78125 in⁴.
The distance to the top is approximately 2.944444 in, while the distance to the bottom is 9.055556 in. Therefore S_x,top is approximately 58.910377 in³ and S_x,bottom approximately 19.154908 in³. Using H/2 for both distances would be wrong for this T-section.
These are elastic geometric section moduli about the specified centroidal axis. They are not plastic moduli, effective-section values or allowable bending moments. Material behavior, section classification, stability and the actual load case still require separate assessment.
Polar area moment versus torsion constant
The perpendicular-axis relationship gives J_p=I_x+I_y for the planar area about the centroid. That is the reported polar second moment of area.
For non-circular sections, torsional behavior generally involves warping and an appropriate torsion constant rather than simply J_p. Oasys GSA's torsion-constant theory explicitly distinguishes the torsion constant from polar moment for non-circular bars. This calculator does not solve warping or calculate a general torsion constant.
Do not use the displayed J_p to claim torsional stiffness or a safe torque for an I-section, T-section or rectangle. Torsional stiffness would also involve material behavior and an appropriate model; those inputs are absent here.
Radii of gyration and section-modulus limits
The area radius of gyration is r=√(I/A) about the chosen axis. It expresses an area-distribution measure as a length. Mississippi State University's geometric-properties reference covers area radii of gyration. A radius of gyration is not automatically a physical radius or a member's unsupported length.
A larger geometric radius by itself does not establish column capacity: effective length, boundary conditions, material properties, local behavior and the relevant design method are outside this page. Similarly, S=I/c is an elastic geometric property; it does not supply yield strength, allowable stress or a resistance factor.
The top and bottom S_x values use the actual distances from the calculated centroid. S_y has equal left/right values for the supported vertical symmetry. A different unsymmetric or rotated section needs an appropriate general analysis rather than these symmetry assumptions.
Precision, validation and idealizations
Active dimensions must be positive unsigned decimals with up to 18 decimal places, without signs, commas or exponents. Each dimension is limited to 100 m as a software bound. Twice the wall thickness must be less than each relevant outer dimension. A web must be narrower than its flange; I-section flanges require 2t_f<H and a T flange requires t_f<H.
Changing units retains the number, so re-enter the converted dimension. Shape changes retain inactive values but exclude them from the calculation. Invalid entries clear the old result and focus the relevant field. Geometry-source notes accept up to 500 characters.
Dimension arithmetic and void subtraction use rational decimal values, with a 50-decimal approximation to π for circular areas. Square roots are approximate. Results display up to six decimal places or scientific notation, and copied values use 15 significant digits. That precision cannot compensate for uncertain dimensions or omitted fillets and tolerances.
The tool does not calculate mass properties, elastic stiffness, transformed multi-material sections, arbitrary-axis rotation, plastic modulus, effective area, stress, deflection, buckling, load capacity or code approval. For a real rolled, formed or fabricated member, use the applicable verified section information and professional assessment.
Frequently asked questions
Are I_x and I_y about the bottom and left edges?
No. They are about horizontal and vertical centroidal axes. The centroid coordinates are measured from the bounding-box origin, but that does not move the reported inertia axes to the edges.
Why are top and bottom section moduli different for a T?
Its centroid is generally closer to the top flange. Dividing the same I_x by different extreme-fiber distances produces different elastic section moduli. The displayed orientation always places the T flange at the top.
Can I use catalog dimensions and expect an exact catalog result?
Not necessarily. This model uses sharp-corner ideal shapes without fillets, taper, weld buildup or product-specific tolerances. Confirm the actual section's published properties and their basis.
Is J_p the torsion constant?
It is a polar area moment. For a general non-circular section, it must not be substituted for the torsion constant. No torsional stiffness or capacity calculation is provided.
Can the tool handle an angle or a channel?
No. Those are outside the six supported shapes. The zero product of inertia and other symmetry statements here must not be carried over to an unsupported shape.
Does a positive result mean the section is adequate?
No. Positive area and second moments describe valid input geometry within this model. They do not establish a safe member, connection, support, load case or design.
Methods, sources and corrections
All worked examples are original fictional geometry scenarios. Independent reference tests use exact fractions and integration about the origin before shifting the complete section to its centroid, with high-precision circular calculations and square roots. This checks the production composite-area method using a separate formulation.
The linked Engineering Statics sections support centroidal-axis and parallel-axis methods; the university reference covers radii of gyration; Oasys explains the torsion distinction. Technical review completed by Riya Kulkarni | BE Civil Engineer; completion confirmed on 14 November 2026. See Civilable's methods and corrections policy and contact Civilable with exact dimensions, units, shape orientation and the expected reference calculation if you find an error.