Formula and worked example
For each section, net area = gross area − full-depth openings. Section concrete volume = net area × that section’s concrete thickness. Add the section volumes, then multiply by (1 + volume allowance ÷ 100). Convert cubic feet to cubic yards by dividing by 27.
Example: a 12 ft × 10 ft patio section has 120 ft² gross area. At an entered 4 in thickness, it contains 40 ft³. With an editable 5% allowance, required volume is 42 ft³, or 1.5555555556 yd³ and 1.189307556864 m³. Dimensions, thickness and allowance are arithmetic examples, not approved patio specifications.
Sections and different thicknesses
Split an L-shaped outline into non-overlapping rectangles, each with its own length, width and thickness. The calculator sums volumes, rather than multiplying total area by an average thickness. Up to 10 sections can be entered. Each section must have positive net area and a uniform thickness.
Example: a 12 ft × 10 ft section at 4 in contains 40 ft³. A separate 6 ft × 4 ft section at 6 in contains 12 ft³. Together they contain 52 ft³; 5% allowance gives 54.6 ft³. If the rectangles overlap at the inside corner, correct their measurements first. Scalar area inputs cannot identify or remove geometric overlap.
Openings remove concrete through the full thickness
Use openings for planting beds, tree openings or other voids that extend through a section’s concrete. Match the selected area unit and deduct each opening only once in its own section. Shallow recesses, drains with partial-depth details, steps and thickened bands need a separate volume takeoff. This calculator cannot locate openings or verify that their outlines fit.
In the default 120 ft² section, a 12 ft² full-depth opening leaves 108 ft². At 4 in thickness the section contains 36 ft³. With 5% allowance it needs 37.8 ft³, exactly 1.4 yd³. Do not subtract the opening again if the source area was already net.
Known gross area for irregular outlines
For a circular or irregular patio, determine its gross area separately with the Square Footage Calculator or project takeoff, then choose known gross section area. The known area is before the openings entered here. Keep different thickness zones in separate sections and avoid combining areas that overlap. Area selectors retain their numbers; length selectors convert valid measurements.
Independent metric reference
A 4 m × 3 m section minus 1 m² of openings leaves 11 m². At 0.10 m thickness it contains 1.1 m³. A separate 2 m × 2 m section minus 0.5 m² of openings at 0.20 m thickness contains 0.7 m³. Combined concrete is 1.8 m³. A user-entered 10% allowance gives 1.98 m³. Openings are deducted at their own section thicknesses.
Allowance, order quantity and scope
Volume allowance applies once after all section volumes are combined. The 5% starting value is an editable example, not a universal waste recommendation. Choose an allowance for the actual measurement and placement conditions. No supplier order increment, delivery count, minimum order or price is automatically applied.
When transferring this allowance-adjusted volume to the Concrete Cost or Concrete Bag Calculator, avoid applying the same allowance a second time. Confirm ordering increments and the actual product with the supplier.
The geometry assumes flat sections with constant thickness within each. No slope, thickened edge, step, footing, curb, subbase, reinforcement, joint layout or drainage quantity is inferred. The tool does not select thickness, concrete strength, load capacity or a structural design. Obtain those details from the responsible project team.
Units, precision and limits
Dimensions accept ft, in, yd, m, cm and mm. Area/openings accept ft² or m² independently for each section. One square foot equals exactly 0.09290304 m²; one cubic foot equals 0.028316846592 m³. Reduced fractions preserve entered decimal geometry and unit conversions before display rounding to three decimals.
Use 1–10 sections. Dimensions support 0.000001–1,000,000 ft after conversion. Combined gross area is capped at 1 billion ft²; base and allowance-adjusted concrete at 1 billion ft³. Allowance accepts 0–100%, and decimal inputs accept up to 18 decimal places. Openings must be nonnegative and smaller than the section’s gross area. These are entry checks, not construction recommendations.
Reference
NRMCA CIP 31: Ordering Ready Mixed Concrete discusses volume-based ordering and communication of project requirements to the producer. Civilable separates measured geometric quantity from an explicit allowance. No patio design, mix, strength or supplier order rule is derived from the reference.